Posted in

What are the steps in maintaining surgical instruments?

As a surgical instrument supplier, I get asked this question all the time – usually by new OR managers, operating room nurses who just started their roles, or even doctors who pick up a scalpel and wonder why their favorite forceps are suddenly slipping. Let me tell you straight: maintaining surgical instruments isn’t just about “cleaning them after use” – it’s the difference between an instrument that works smoothly for 10 years and one that’s rusted shut after 3 surgeries. I’ve seen it both ways, and trust me, the latter causes way more headaches (and sometimes, even delays in procedures). Surgical Instruments

I break down the process into 5 real, actionable steps – no fancy jargon, just what we actually train our clients to do. Let’s walk through each one, because skipping even a tiny step here can mess everything up.

First step: Immediate post-use processing. I know, after a long surgery, you’re tired. Scrub techs want to grab a break, surgeons are heading to their next case, and the instrument tray’s been sitting on the operating room table for 45 minutes. But here’s the thing – organic debris (blood, tissue, pus) starts to dry on metal instruments faster than you think. If you let that dry, you’re basically gluing it to the surface, and that stuff is way harder to remove later. What we tell our clients to do: grab a soft, lint-free cloth (not paper towels – those leave fuzz) or a small brush, rinse the instruments with lukewarm (not hot – hot water sets protein debris) tap water right after the case. For tricky spots, like the hinge of forceps or the teeth of hemostats, use a gentle stream of water to blast out any gunk. Don’t soak them yet – soaking too early can let some debris seep into hinges, which we don’t want. Just get the visible stuff off first.

Second step: Deep cleaning, the right way. This is where a lot of people go wrong – they use regular dish soap or harsh bleach, and that damages the metal. Surgical instruments are usually made of stainless steel, but even stainless steel can corrode if you use the wrong cleaners. Here’s the trick: use an enzymatic cleaner made specifically for surgical tools. These are designed to break down protein-based debris, and they’re gentle on metal. Fill a basin with lukewarm water, add the enzyme cleaner, and submerge the instruments – but make sure to open hinged instruments (forceps, scissors, retractors) fully so the cleaner gets inside. Let them soak for the time the cleaner says (usually 5 to 10 minutes – don’t leave them longer than that). Then, use a soft-bristled nylon brush to scrub every nook: the serrated edges of scissors, the ratchets on hemostats, the holes in needle holders. Avoid metal brushes here – they can scratch the surface, which creates tiny spots where bacteria can hide and corrosion can start. Once you’re done, rinse them thoroughly again with lukewarm water to get all the cleaner off.

Third step: Inspection and function testing. This step is non-negotiable, but a lot of teams rush through it. After cleaning, you have to check every single instrument for two things: damage and function. Damage first – look for rust, dents, broken tips, or loose screws. If a scalpel blade has a tiny nick, it can slip mid-incision, which is dangerous. If a forceps tip is misaligned, you’ll crush tissue instead of gripping it properly. Then function: test every hinge. Open and close scissors 10 times – they should glide smoothly, not stick or feel tight. Test hemostat ratchets – they should lock securely at each position, no play. Needle holders should clamp a needle firmly without slipping. This is where we see a lot of small issues that turn into big problems. For example, I had a client who skipped this step and used a pair of scissors with a bent hinge – it split a patient’s tissue during a biopsy, and they had to order a replacement. Don’t let that happen.

Fourth step: Drying completely – no shortcuts. I’ve seen teams wipe instruments with a cloth and call it dry. That’s not enough. If moisture is left on the metal, even a tiny drop, it will cause rust. What you need to do: first, use a lint-free cloth to wipe as much moisture as possible, then place all instruments on a drying rack, hinged open, in a low-humidity area (the OR’s storage closet works, just not near a sink or humidifier). Some teams use compressed air to blow out moisture from hinges – just make sure the compressed air is dry (no water in the line) so you don’t add more moisture. Let them dry for at least 30 minutes, maybe an hour for larger instruments like retractors. Never put wet instruments into a storage tray – that’s a recipe for rust.

Fifth step: Proper storage. Once they’re dry, how you store them matters a lot. Don’t just toss them into a drawer with other tools – they can scratch each other, which leads to corrosion. We recommend using custom trays that separate instruments by type, with foam inserts that hold each tool in place. For hinged instruments, leave them slightly open (not all the way closed) so air can circulate around the hinge. Keep storage areas at a consistent temperature and humidity – below 60% humidity is ideal, and avoid areas with direct sunlight, which can fade any markings on instruments (like size labels, which you need to identify the right tool fast). Also, label trays clearly so you don’t mix up forceps with scissors – that’s a waste of time and can lead to using the wrong instrument during a procedure.

Wait, let’s add a quick pro tip from our team – we’ve noticed that a lot of clients use the same cleaning solution for weeks. That’s a mistake. Enzymatic cleaners lose their effectiveness after about 24 hours, so you should make a fresh batch every time you do a cleaning. Also, if an instrument has a biological hazard (like from a case with a virus), you should bag it separately before processing to avoid cross-contamination.

Now, I know what some of you are thinking: “That sounds like a lot of work.” But here’s the reality – when you maintain your instruments properly, they last 2 to 3 times longer than if you skip steps. We’ve had clients who’ve used the same set of hemostats for 8 years because they follow these steps, whereas another client who rushed maintenance had to replace theirs every 2 years. It saves money in the long run, and more importantly, it keeps procedures safe.

If you’re a hospital manager, scrub tech, or OR lead who’s struggling with instrument maintenance – maybe your team is cutting corners, or you keep dealing with rusty tools mid-surgery – let’s chat. We work with all types of surgical facilities, from small outpatient clinics to large academic hospitals, and we can help you set up a maintenance routine that fits your schedule. We also sell high-quality, durable instruments that are built to handle regular maintenance, so you don’t have to worry about them breaking when you need them most. Hit us up to talk through what you need – no sales pitch, just straight talk about making your OR run smoother.

Ultrasonic Surgical System References

  1. Association of periOperative Registered Nurses (AORN). “Recommended Practices for Cleaning, Handling, and Processing Surgical Instruments.” AORN Guidelines for Perioperative Practice, 2023.
  2. World Health Organization (WHO). “Manual for Cleaning and Disinfection of Medical Devices.” WHO Press, 2021.
  3. American College of Surgeons (ACS). “Instrument Care and Maintenance for Operating Rooms.” ACS Surgery News, vol. 38, no. 5, 2022.

Jiangsu Bonss Medical Technology Co., Ltd.
As one of the most professional surgical instruments manufacturers and suppliers in China, we’re featured by quality products and good price. Please rest assured to buy bulk surgical instruments for sale here from our factory. Customized orders are welcome.
Address: Building #7,No.898,China Medical City Avenue, Haling District, Taizhou City.Jiangsu P.R. China
E-mail: inquiry@plasma-surgical.com
WebSite: https://www.bonssmedical.com/