As an oxygen generator supplier who has spent over a decade helping hospitals, research labs, and industrial facilities keep their oxygen supply systems running reliably, I get asked one question more than any other: “Do oxygen generators need to be calibrated?” It’s a fair question, and one that comes up most often after a facility has invested tens of thousands of dollars in a new system—they want to make sure they’re getting every last drop of the output they paid for, and that that output is as pure as they need it to be. Let me break this down straight, no corporate jargon, just the lessons I’ve learned working side by side with our clients across 12 countries. Oxygen Generator

First, let’s start with what an oxygen generator actually does, because calibration only makes sense when you understand the job. Most of the systems we sell are pressure swing adsorption (PSA) units, right? They work by pumping compressed air into a tank full of molecular sieve material that catches nitrogen, water vapor, and other impurities, leaving 90-95% pure oxygen to send to your tank or pipeline. For a hospital, that means every patient on supplemental oxygen gets consistent, safe levels; for a brewer, it means preserving the flavor of their beer without unwanted oxidation; for a fish farm, it means enough oxygen to keep thousands of tilapia alive in a closed loop system.
Here’s the thing: PSA oxygen generators aren’t set-it-and-forget-it machines. Even the highest-quality units we manufacture and install don’t stay perfectly accurate on their own, and that’s not a flaw—it’s just how the process works. Let’s talk about why calibration matters first, before we get into how and when to do it. If an oxygen generator is off, the risks aren’t just minor. For medical clients, if the oxygen purity drops below 90%, patients might not get enough oxygen, leading to longer hospital stays or even worse outcomes. For industrial clients, a brewer might end up with a batch of beer that’s flat or has off-flavors; a metal fabrication shop might use too much oxygen, wasting money on electricity and sieve material. Even a small drift of 1-2% in purity can add up to thousands of dollars in wasted supplies or missed opportunities over a year.
Now, what is calibration, exactly? It’s the process of verifying and adjusting the generator’s sensors and controls to match a known, accurate standard. For oxygen generators, this usually means testing the actual output purity with a certified oxygen analyzer, then adjusting the PSA cycle timing, pressure levels, and sieve bed operation to get back to the target purity (most medical units target 93% ± 2% purity, while industrial units can vary a bit depending on use). It’s not a guesswork process—you can’t just “eyeball” it; you need to compare the generator’s readings to a reference tool that’s traceable to national standards, like those set by the National Institute of Standards and Technology (NIST) here in the U.S., or equivalent bodies around the world.
A lot of our clients tell me they check their generator’s display every month, and it says 93% purity, so it must be fine. But here’s a common misconception: the built-in sensors on oxygen generators are not primary standards. They drift over time. Just like your car’s speedometer might be slightly off after a few years of bumpy roads, or your home thermostat might not read the exact temperature of your room, those on-board sensors lose accuracy. We’ve seen units that display 93% purity for months, but when we run a calibration test with a portable reference analyzer, the actual output is 89%—low enough to be a problem for a hospital. That’s why calibration isn’t optional; it’s a critical part of maintaining the generator’s performance over its 10-15 year lifespan.
Let’s break down why calibration is necessary. First, sieve material degradation. The molecular sieve inside the generator doesn’t last forever. Over time, the small beads that catch nitrogen break down, get dirty from dust or moisture in the compressed air, and lose their ability to separate nitrogen from oxygen. A generator that was calibrated when new might start to output lower purity as the sieve wears, and without calibration, you won’t know that it needs more compressed air, longer cycle times, or even a sieve replacement. We had a client in rural Kenya a couple years ago who ignored calibration for two years, and their sieve was so worn that the generator was working 20% harder than it needed to, wasting electricity. When we calibrated it and replaced the sieve, their energy use dropped by 18%—that’s real cost savings.
Second, sensor drift. On-board oxygen sensors are usually zirconia or electrochemical types. Electrochemical sensors, which are common in smaller units, can degrade in 2-3 years, even if the generator is sitting idle. Zirconia sensors last longer, 5-7 years, but they still drift with temperature changes and humidity. For example, if a generator is installed in a hot, dusty warehouse, the heat can make the sensor read higher than actual purity, leading the unit to cut off the cycle early and waste oxygen. If it’s in a cold storage room, the opposite happens: the sensor reads low, so the unit runs longer, using more electricity. Calibration fixes that drift by resetting the sensor to match a known standard.
Third, component wear. The valves that control the PSA cycle—electromagnetic valves, check valves, and pressure regulators—all wear out over time. A valve that’s not opening or closing fully can let extra nitrogen into the oxygen stream, lowering purity, or let oxygen escape, reducing output volume. Calibration isn’t just about adjusting the sensors; it’s also about testing the valves and cycle timing to make sure they’re working as they should. We had a client in a small metal shop last year who thought his generator was only outputting 5 LPM of oxygen, but after calibration, we found a leaking valve, fixed it, and the output jumped to 8 LPM—enough for two extra welding stations without needing to buy a bigger generator.
Now, when do you need to calibrate? We recommend two levels: routine calibration and event-based calibration. Routine calibration should be done every 6 to 12 months, depending on the use case. Medical generators, which have strict regulatory requirements (like FDA in the U.S. or CE marking in Europe), should be calibrated every 6 months to stay compliant. Industrial generators, used in less regulated settings, can go 12 months, but we still suggest every 9 months for best performance. For smaller, portable oxygen concentrators (which are a type of oxygen generator, too), calibration should be done every 12 months, or after any heavy use, like being moved between job sites.
Event-based calibration is when you should schedule a calibration right away, no matter when your last one was. If your generator’s display is showing fluctuations more than usual—like it jumps from 90% to 95% in a minute. If you notice a spike in your electricity bill with no other changes. If you replace any major parts: sieve material, valves, sensors, or the compressor. If you move the generator to a new location (especially one with different temperature or humidity levels). And, of course, if you suspect your oxygen output is too low for your needs—like a hospital patient saying they’re still short of breath, or a brewer noticing their beer oxidation is higher than normal.
Wait, but what if you have a very small generator, like for home use? A lot of our individual customers ask if their home oxygen concentrator needs calibration. The short answer is yes, even for personal use. If your concentrator is outputting lower purity, you’re not getting the therapeutic benefit you need, and that can be dangerous for people with respiratory conditions. We have a line of home-use concentrators that come with a built-in calibration prompt, but even if you have an older model, a calibration every 12 months is a good idea.
Now, let’s address a common pushback: “I can do this myself, right?” Technically, you can buy a portable oxygen analyzer and do a calibration on your own, but I don’t recommend it for most people. Calibration isn’t just measuring the output; it’s adjusting the generator’s controls correctly. If you don’t know how to adjust the PSA cycle timing or pressure, you can make the problem worse. For example, we had a client who tried to calibrate his generator at home, and he adjusted the pressure too high, which damaged the sieve beyond repair, costing him more in sieve replacement than a professional calibration would have. Also, for medical facilities, many regulatory bodies require calibration to be done by a certified technician, and to have a documented record of the calibration for compliance audits. That’s not just a suggestion—it’s a requirement for hospitals, nursing homes, and clinics.
What about when you get a new oxygen generator? We always do a full pre-delivery calibration before the unit leaves our warehouse, but we still recommend a post-installation calibration within the first month of use, just to make sure the unit performed well during shipping and installation. Sometimes a valve can shift during transport, or a pipe connection can have a small leak, and a calibration catches that early.
Let me share a real example from a client I worked with last year. A mid-sized hospital in Lima, Peru, had a PSA oxygen generator that was installed 3 years prior. They were having trouble with some patients not getting enough oxygen, so they called us. When we did a calibration test, we found the oxygen purity was 87%—way below the 93% they needed. The sieve was worn, and the main oxygen sensor had drifted by 5% over 2 years. We calibrated the unit, replaced the sieve, and installed a new reference sensor for regular checks. After that, the hospital’s patient outcomes improved, and their oxygen-related energy use dropped by 14%—that’s not just a win for performance, it’s a win for their budget and their patients.
Now, I know some people think calibration is an extra cost, but it’s an investment. Let’s do the math: a professional calibration for a mid-sized medical oxygen generator costs around $300-$500, depending on location. If a 1% drop in purity leads to 5% higher electricity use, and your generator uses $1,000 a month in electricity, that’s $60 extra a month, or $720 a year. Over two years, that’s more than the cost of two calibrations. Add to that the cost of a bad batch of beer, or a patient’s extended hospital stay, and calibration is clearly worth it.
So, to circle back to the original question: yes, oxygen generators do need to be calibrated. It’s not a optional step, it’s a necessary one to keep your system performing safely, efficiently, and in compliance with regulations. But not all calibrations are the same—you need a technician who knows your specific generator model, who uses traceable reference standards, and who can adjust the system properly, not just take a reading.

If you’re noticing issues with your oxygen output, haven’t calibrated your generator in over a year, or are just looking to make sure your system is running at peak performance, don’t wait. Our team has certified technicians around the world who can perform calibrations on all makes and models of PSA oxygen generators, as well as provide regular maintenance to keep your system working for years. Reach out to our team of oxygen generator suppliers today to schedule a consultation, answer any questions about your specific unit, or get a quote for calibration and maintenance services. It’s the easiest way to protect your investment and ensure you always have the oxygen supply you need.
Screw Gas Compressor References
- Molecular Sieve Fundamentals for Pressure Swing Adsorption, American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2021
- Medical Gas Equipment Calibration Requirements and Best Practices, Joint Commission Resources, 2022
- PSA Oxygen Generator Performance Standards, International Organization for Standardization, ISO 13485:2016
- Electrochemical Oxygen Sensor Degradation Rates, Sensors and Actuators B: Chemical, Vol. 267, 2018
- Industrial Oxygen Generator Efficiency and Calibration Guidelines, U.S. Department of Energy, Industrial Technologies Program, 2020