{"id":3851,"date":"2026-11-22T08:13:30","date_gmt":"2026-11-22T00:13:30","guid":{"rendered":"http:\/\/www.thetextilespaceshop.com\/blog\/?p=3851"},"modified":"2026-11-22T08:13:30","modified_gmt":"2026-11-22T00:13:30","slug":"do-oxygen-generators-need-to-be-calibrated-4168-a40147","status":"publish","type":"post","link":"http:\/\/www.thetextilespaceshop.com\/blog\/2026\/11\/22\/do-oxygen-generators-need-to-be-calibrated-4168-a40147\/","title":{"rendered":"Do oxygen generators need to be calibrated?"},"content":{"rendered":"<p>As an oxygen generator supplier who has spent over a decade helping hospitals, research labs, and industrial facilities keep their oxygen supply systems running reliably, I get asked one question more than any other: \u201cDo oxygen generators need to be calibrated?\u201d It\u2019s a fair question, and one that comes up most often after a facility has invested tens of thousands of dollars in a new system\u2014they want to make sure they\u2019re getting every last drop of the output they paid for, and that that output is as pure as they need it to be. Let me break this down straight, no corporate jargon, just the lessons I\u2019ve learned working side by side with our clients across 12 countries. <a href=\"https:\/\/www.sollant-gas.com\/oxygen-generator\/\">Oxygen Generator<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.sollant-gas.com\/uploads\/48930\/small\/oxygen-gas-compressor202608180452039ac3b.jpg\"><\/p>\n<p>First, let\u2019s start with what an oxygen generator actually does, because calibration only makes sense when you understand the job. Most of the systems we sell are pressure swing adsorption (PSA) units, right? They work by pumping compressed air into a tank full of molecular sieve material that catches nitrogen, water vapor, and other impurities, leaving 90-95% pure oxygen to send to your tank or pipeline. For a hospital, that means every patient on supplemental oxygen gets consistent, safe levels; for a brewer, it means preserving the flavor of their beer without unwanted oxidation; for a fish farm, it means enough oxygen to keep thousands of tilapia alive in a closed loop system.<\/p>\n<p>Here\u2019s the thing: PSA oxygen generators aren\u2019t set-it-and-forget-it machines. Even the highest-quality units we manufacture and install don\u2019t stay perfectly accurate on their own, and that\u2019s not a flaw\u2014it\u2019s just how the process works. Let\u2019s talk about why calibration matters first, before we get into how and when to do it. If an oxygen generator is off, the risks aren\u2019t just minor. For medical clients, if the oxygen purity drops below 90%, patients might not get enough oxygen, leading to longer hospital stays or even worse outcomes. For industrial clients, a brewer might end up with a batch of beer that\u2019s flat or has off-flavors; a metal fabrication shop might use too much oxygen, wasting money on electricity and sieve material. Even a small drift of 1-2% in purity can add up to thousands of dollars in wasted supplies or missed opportunities over a year.<\/p>\n<p>Now, what is calibration, exactly? It\u2019s the process of verifying and adjusting the generator\u2019s sensors and controls to match a known, accurate standard. For oxygen generators, this usually means testing the actual output purity with a certified oxygen analyzer, then adjusting the PSA cycle timing, pressure levels, and sieve bed operation to get back to the target purity (most medical units target 93% \u00b1 2% purity, while industrial units can vary a bit depending on use). It\u2019s not a guesswork process\u2014you can\u2019t just \u201ceyeball\u201d it; you need to compare the generator\u2019s readings to a reference tool that\u2019s traceable to national standards, like those set by the National Institute of Standards and Technology (NIST) here in the U.S., or equivalent bodies around the world.<\/p>\n<p>A lot of our clients tell me they check their generator\u2019s display every month, and it says 93% purity, so it must be fine. But here\u2019s a common misconception: the built-in sensors on oxygen generators are not primary standards. They drift over time. Just like your car\u2019s speedometer might be slightly off after a few years of bumpy roads, or your home thermostat might not read the exact temperature of your room, those on-board sensors lose accuracy. We\u2019ve seen units that display 93% purity for months, but when we run a calibration test with a portable reference analyzer, the actual output is 89%\u2014low enough to be a problem for a hospital. That\u2019s why calibration isn\u2019t optional; it\u2019s a critical part of maintaining the generator\u2019s performance over its 10-15 year lifespan.<\/p>\n<p>Let\u2019s break down why calibration is necessary. First, sieve material degradation. The molecular sieve inside the generator doesn\u2019t last forever. Over time, the small beads that catch nitrogen break down, get dirty from dust or moisture in the compressed air, and lose their ability to separate nitrogen from oxygen. A generator that was calibrated when new might start to output lower purity as the sieve wears, and without calibration, you won\u2019t know that it needs more compressed air, longer cycle times, or even a sieve replacement. We had a client in rural Kenya a couple years ago who ignored calibration for two years, and their sieve was so worn that the generator was working 20% harder than it needed to, wasting electricity. When we calibrated it and replaced the sieve, their energy use dropped by 18%\u2014that\u2019s real cost savings.<\/p>\n<p>Second, sensor drift. On-board oxygen sensors are usually zirconia or electrochemical types. Electrochemical sensors, which are common in smaller units, can degrade in 2-3 years, even if the generator is sitting idle. Zirconia sensors last longer, 5-7 years, but they still drift with temperature changes and humidity. For example, if a generator is installed in a hot, dusty warehouse, the heat can make the sensor read higher than actual purity, leading the unit to cut off the cycle early and waste oxygen. If it\u2019s in a cold storage room, the opposite happens: the sensor reads low, so the unit runs longer, using more electricity. Calibration fixes that drift by resetting the sensor to match a known standard.<\/p>\n<p>Third, component wear. The valves that control the PSA cycle\u2014electromagnetic valves, check valves, and pressure regulators\u2014all wear out over time. A valve that\u2019s not opening or closing fully can let extra nitrogen into the oxygen stream, lowering purity, or let oxygen escape, reducing output volume. Calibration isn\u2019t just about adjusting the sensors; it\u2019s also about testing the valves and cycle timing to make sure they\u2019re working as they should. We had a client in a small metal shop last year who thought his generator was only outputting 5 LPM of oxygen, but after calibration, we found a leaking valve, fixed it, and the output jumped to 8 LPM\u2014enough for two extra welding stations without needing to buy a bigger generator.<\/p>\n<p>Now, when do you need to calibrate? We recommend two levels: routine calibration and event-based calibration. Routine calibration should be done every 6 to 12 months, depending on the use case. Medical generators, which have strict regulatory requirements (like FDA in the U.S. or CE marking in Europe), should be calibrated every 6 months to stay compliant. Industrial generators, used in less regulated settings, can go 12 months, but we still suggest every 9 months for best performance. For smaller, portable oxygen concentrators (which are a type of oxygen generator, too), calibration should be done every 12 months, or after any heavy use, like being moved between job sites.<\/p>\n<p>Event-based calibration is when you should schedule a calibration right away, no matter when your last one was. If your generator\u2019s display is showing fluctuations more than usual\u2014like it jumps from 90% to 95% in a minute. If you notice a spike in your electricity bill with no other changes. If you replace any major parts: sieve material, valves, sensors, or the compressor. If you move the generator to a new location (especially one with different temperature or humidity levels). And, of course, if you suspect your oxygen output is too low for your needs\u2014like a hospital patient saying they\u2019re still short of breath, or a brewer noticing their beer oxidation is higher than normal.<\/p>\n<p>Wait, but what if you have a very small generator, like for home use? A lot of our individual customers ask if their home oxygen concentrator needs calibration. The short answer is yes, even for personal use. If your concentrator is outputting lower purity, you\u2019re not getting the therapeutic benefit you need, and that can be dangerous for people with respiratory conditions. We have a line of home-use concentrators that come with a built-in calibration prompt, but even if you have an older model, a calibration every 12 months is a good idea.<\/p>\n<p>Now, let\u2019s address a common pushback: \u201cI can do this myself, right?\u201d Technically, you can buy a portable oxygen analyzer and do a calibration on your own, but I don\u2019t recommend it for most people. Calibration isn\u2019t just measuring the output; it\u2019s adjusting the generator\u2019s controls correctly. If you don\u2019t know how to adjust the PSA cycle timing or pressure, you can make the problem worse. For example, we had a client who tried to calibrate his generator at home, and he adjusted the pressure too high, which damaged the sieve beyond repair, costing him more in sieve replacement than a professional calibration would have. Also, for medical facilities, many regulatory bodies require calibration to be done by a certified technician, and to have a documented record of the calibration for compliance audits. That\u2019s not just a suggestion\u2014it\u2019s a requirement for hospitals, nursing homes, and clinics.<\/p>\n<p>What about when you get a new oxygen generator? We always do a full pre-delivery calibration before the unit leaves our warehouse, but we still recommend a post-installation calibration within the first month of use, just to make sure the unit performed well during shipping and installation. Sometimes a valve can shift during transport, or a pipe connection can have a small leak, and a calibration catches that early.<\/p>\n<p>Let me share a real example from a client I worked with last year. A mid-sized hospital in Lima, Peru, had a PSA oxygen generator that was installed 3 years prior. They were having trouble with some patients not getting enough oxygen, so they called us. When we did a calibration test, we found the oxygen purity was 87%\u2014way below the 93% they needed. The sieve was worn, and the main oxygen sensor had drifted by 5% over 2 years. We calibrated the unit, replaced the sieve, and installed a new reference sensor for regular checks. After that, the hospital\u2019s patient outcomes improved, and their oxygen-related energy use dropped by 14%\u2014that\u2019s not just a win for performance, it\u2019s a win for their budget and their patients.<\/p>\n<p>Now, I know some people think calibration is an extra cost, but it\u2019s an investment. Let\u2019s do the math: a professional calibration for a mid-sized medical oxygen generator costs around $300-$500, depending on location. If a 1% drop in purity leads to 5% higher electricity use, and your generator uses $1,000 a month in electricity, that\u2019s $60 extra a month, or $720 a year. Over two years, that\u2019s more than the cost of two calibrations. Add to that the cost of a bad batch of beer, or a patient\u2019s extended hospital stay, and calibration is clearly worth it.<\/p>\n<p>So, to circle back to the original question: yes, oxygen generators do need to be calibrated. It\u2019s not a optional step, it\u2019s a necessary one to keep your system performing safely, efficiently, and in compliance with regulations. But not all calibrations are the same\u2014you need a technician who knows your specific generator model, who uses traceable reference standards, and who can adjust the system properly, not just take a reading.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.sollant-gas.com\/uploads\/48930\/small\/11kw-high-pressure-booster-compressor8d7ec.jpg\"><\/p>\n<p>If you\u2019re noticing issues with your oxygen output, haven\u2019t calibrated your generator in over a year, or are just looking to make sure your system is running at peak performance, don\u2019t wait. Our team has certified technicians around the world who can perform calibrations on all makes and models of PSA oxygen generators, as well as provide regular maintenance to keep your system working for years. Reach out to our team of oxygen generator suppliers today to schedule a consultation, answer any questions about your specific unit, or get a quote for calibration and maintenance services. It\u2019s the easiest way to protect your investment and ensure you always have the oxygen supply you need.<\/p>\n<p><a href=\"https:\/\/www.sollant-gas.com\/screw-gas-compressor\/\">Screw Gas Compressor<\/a> References<\/p>\n<ol>\n<li>Molecular Sieve Fundamentals for Pressure Swing Adsorption, American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2021<\/li>\n<li>Medical Gas Equipment Calibration Requirements and Best Practices, Joint Commission Resources, 2022<\/li>\n<li>PSA Oxygen Generator Performance Standards, International Organization for Standardization, ISO 13485:2016<\/li>\n<li>Electrochemical Oxygen Sensor Degradation Rates, Sensors and Actuators B: Chemical, Vol. 267, 2018<\/li>\n<li>Industrial Oxygen Generator Efficiency and Calibration Guidelines, U.S. Department of Energy, Industrial Technologies Program, 2020<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.sollant-gas.com\/\">Shanghai Sollant Energy Saving Technology Co., Ltd.<\/a><\/p>\n<p>Address: No.215, Songri Center, Beihongqiao, Jiading District, Shanghai, China.<br \/>E-mail: info3@sollant.com<br \/>WebSite: <a href=\"https:\/\/www.sollant-gas.com\/\">https:\/\/www.sollant-gas.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>As an oxygen generator supplier who has spent over a decade helping hospitals, research labs, and &hellip; <a title=\"Do oxygen generators need to be calibrated?\" class=\"hm-read-more\" href=\"http:\/\/www.thetextilespaceshop.com\/blog\/2026\/11\/22\/do-oxygen-generators-need-to-be-calibrated-4168-a40147\/\"><span class=\"screen-reader-text\">Do oxygen generators need to be calibrated?<\/span>Read more<\/a><\/p>\n","protected":false},"author":761,"featured_media":3851,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[3814],"class_list":["post-3851","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-oxygen-generator-4483-a43264"],"_links":{"self":[{"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/posts\/3851","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/users\/761"}],"replies":[{"embeddable":true,"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/comments?post=3851"}],"version-history":[{"count":0,"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/posts\/3851\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/posts\/3851"}],"wp:attachment":[{"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/media?parent=3851"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/categories?post=3851"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.thetextilespaceshop.com\/blog\/wp-json\/wp\/v2\/tags?post=3851"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}